Sign In | Join Free | My burrillandco.com
Home > Surge Protection Device SPD >

CE Spd Surge Protective Device 100kA High Current Leakage Capability

    Buy cheap CE Spd Surge Protective Device 100kA High Current Leakage Capability from wholesalers
     
    Buy cheap CE Spd Surge Protective Device 100kA High Current Leakage Capability from wholesalers
    • Buy cheap CE Spd Surge Protective Device 100kA High Current Leakage Capability from wholesalers

    CE Spd Surge Protective Device 100kA High Current Leakage Capability

    Ask Lasest Price
    Brand Name : Uchi
    Model Number : OBV10-I-15/4P
    Certification : CE / SGS / ISO9001
    Price : Negotiate
    Payment Terms : T/T, L/C, Western Union
    Supply Ability : 60000 pieces per month
    Delivery Time : 5-15 days after payment
    • Product Details
    • Company Profile

    CE Spd Surge Protective Device 100kA High Current Leakage Capability

    255/275/320/385VAC Power Surge Protection Device 100kA Power SPD


    OBV10-I-15


    Surge protectors OBV10-I-15 meet the type 1 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions.The voltage-limiting,high-performance spark gaps provide several benefits.A short response time, a low protection level and high current leakage capability with long service life.


    Technical Parameters


    Model: OBV10-I-15-Pluggable
    Maximum continuous operating voltageUcV255/275/320/385
    SPD to EN 61643-11Type 1
    SPD to IEC 61643-1class I
    LPZ0→2
    Lightning impulse current (10/350μs)IimpkA15
    Lightning impulse current (10/350μs) [total]kA60
    Nominal discharge surge current (8/20μs)InkA60
    Maximum discharge surge current (8/20μs)ImaxkA100
    Voltage protection levelUpkV2,5
    Response timetAns<25
    Follow current quenching capacity IpeakIfi peakkA12.5
    Maximum back-up fuseA315
    Temperature rangeϑ°C-40℃~+85℃
    Protection ratingIP 20
    Connection cross-section, rigidmm²10-50
    Connection cross-section, multi-wiremm²10-35
    Connection cross-section, flexiblemm²10-25

    Feature

    • Designed according to IEC 61643-11/EN 61643-1.
    • Red: functionless, immediate replacement required.

    • Easy to install in any standardized distribution pane or control cabinets.


    Application


    ● These devices protect low-voltage consumer systems from overvoltage.
    ● Applied in modular SPD Class I + Class II (Class B + C) for TT and TN-S power supply system.

    Others
    Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

    Type No.Rated Voltage(V) UnContinuous Voltage Uc(V~)Standard Discharge Current In(KA)

    Max Discharge Current
    Imax(KA)

    Protection Level(KA~)Response Time(ns)
    DGM1(2)-D5220/380

    275/320
    385/420

    5101.2≤25
    DGM1(2)-D101021.6
    DGM1(2)-C2020401.8
    DGM13-B303060.2.2
    DGM3(4)-B4010802.4
    DGM(4)-B60601002.8
    DGM-N-PE220/25540/6060/801.2≤100


    Transient voltage surgesin lv power lines
    Transient overvoltages are voltage surges that can reach tens ofkilovolts with a duration of the order of microseconds.Despite theirshort duration, the high energy content can cause serious problemsto equipment connected to the line, from premature aging to destruction, causing disruptions to service and financial loss.Thistype of surge can have various different causes, including atmospheric lightning directly striking the external protection(lightning rods) on a building or transmission line or the associatedinduction of electromagnetic fields on metallic conductors.
    Outdoor and longer lines are the most exposed to these fields,which often receive high levels of induction.
    It is also common for non-weather phenomena, such as transformer centre switching or the disconnection of motors orother inductive loads to cause voltage spikes in adjacent lines.

    What skills should lightning protectors have in the selection?
    1.Confirm power supply system
    First of all, you must determine what your power distribution system is like, whether it is TT, TN or IT system. After determining the power distribution system, you can choose the protection mode and wiring method of the lightning arrester to select the appropriate lightning arrester.
    For example, TN-C uses 3P lightning protection device, TN-S uses 4P, TT uses 3P+N, etc.
    2.Know the main parameters of the lightning arrester.
    FAQ


    Q: Can I get some samples?
    A: Yes, Sample orders welcomed.

    Q: Can I use my own Logo or design on goods?
    A: Yes, Customized logo and design on mass production are available.

    Q:What is the delivery time?
    A: 3 days for samples, 7-15 days for mass production.

    Q: What is the payment term?
    A: T/T, L/C at sight, West union , Paypal, etc.

    Quality CE Spd Surge Protective Device 100kA High Current Leakage Capability for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong Uchi Electronics Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)