Sign In | Join Free | My burrillandco.com
Home > Surge Protection Device SPD >

Graphite Type 1 And Type 2 Surge Protection In 25KA For Data Centers

    Buy cheap Graphite Type 1 And Type 2 Surge Protection In 25KA For Data Centers from wholesalers
     
    Buy cheap Graphite Type 1 And Type 2 Surge Protection In 25KA For Data Centers from wholesalers
    • Buy cheap Graphite Type 1 And Type 2 Surge Protection In 25KA For Data Centers from wholesalers

    Graphite Type 1 And Type 2 Surge Protection In 25KA For Data Centers

    Ask Lasest Price
    Brand Name : Uchi
    Model Number : OBV5-I-25
    Certification : CE / SGS / ISO9001
    Price : Negotiate
    Payment Terms : T/T, L/C, Western Union
    Supply Ability : 60000 pieces per month
    Delivery Time : 5-15 days after payment
    • Product Details
    • Company Profile

    Graphite Type 1 And Type 2 Surge Protection In 25KA For Data Centers

    25ka Type 1+2 Surge Protector / Lightning Arrester For IT/Data centers


    OBV5-I-25


    OBV10-I-25 meet the type 1 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions.The voltage-limiting,high-performance spark gaps provide several benefits.A short response time, a low protection level and high current leakage capability with long service life.


    Technical Parameters


    Model: OBV10-I-25-Pluggable
    Maximum continuous operating voltageUcV255/275/320/385
    SPD to EN 61643-11Type 1+2
    SPD to IEC 61643-1class I+2
    LPZ0→2
    Lightning impulse current (10/350μs)IimpkA25
    Lightning impulse current (10/350μs) [total]kA100
    Nominal discharge surge current (8/20μs)InkA25
    Arrester surge current (8/20μs) [total]kA100
    Voltage protection levelUpkV2,0
    Response timetAns<100
    Follow current quenching capacity IpeakIfi peakkA25
    Maximum back-up fuseA315
    Temperature rangeϑ°C-40℃~+85℃
    Protection ratingIP 20
    Connection cross-section, rigidmm²10-50
    Connection cross-section, multi-wiremm²10-35
    Connection cross-section, flexiblemm²10-25

    Feature&Benefits

    1,Protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage.
    2,Protect transmission of Ethernet signals with 48V DC / 34V AC power supply circuits against
    lightning induced surges.
    3,Enhanced surge protection.
    4,For mounting on 35mm DIN rails acc. to EN 60715.
    5,It can effectively ensure the equipments work properly.
    ·Easy installation or retrofit.
    ·Din-rail mountable.
    ·Fail-safe /self-protected designRemote indicator (optional) with 3pin NO/NC contact.
    ·IP20 finger-safe designVisual indicator.
    ·Small foot print.

    Application


    ●AC/DC distribution
    ●Power supplies
    ●Industrial automation
    ●Telecommunications
    ●Motor controls systems
    ●PLC applications
    ●Power transfer equipment
    ●HVAC applications
    ● AC drives
    ●UPS systems
    ●Security systems
    ●IT/Data centers

    Note: The difference between T1 type and T2 type surge protector


    The T1 type surge protector refers to the product with the lightning test waveform of 10/350us, and the T2 type surge protector refers to the product with the lightning test waveform of 8/20us.

    The main difference between the two types of surge protectors lies in the different test waveforms. The energy of the 10/350us waveform is stronger than the energy of the 8/20us waveform, so in many cases the T1 surge protector is generally 12.5kA, 15kA, 25kA, etc. , T2 surge protector does have 20kA, 40kA, 60KA, 100kA, etc. Although the value of T2 type surge protector looks larger, their test waveforms are different. In fact, the energy of T1 is stronger.

    Therefore, the national standard GB50057-2010 requires the installation of a T1 type surge protector in the main incoming line, which is also the first-level surge protector. When selecting the type, pay attention to the surge protector must have a T1 test Iimp (10/350us) test This parameter is generally Iimp is greater than or equal to 12.5kA, and the protection level Up≤2.5kV is enough.


    Others
    Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

    Type No.Rated Voltage(V) UnContinuous Voltage Uc(V~)Standard Discharge Current In(KA)

    Max Discharge Current
    Imax(KA)

    Protection Level(KA~)Response Time(ns)
    DGM1(2)-D5220/380

    275/320
    385/420

    5101.2≤25
    DGM1(2)-D101021.6
    DGM1(2)-C2020401.8
    DGM13-B303060.2.2
    DGM3(4)-B4010802.4
    DGM(4)-B60601002.8
    DGM-N-PE220/25540/6060/801.2≤100

    The main function of the power surge protector is to introduce the lightning wave into the ground quickly enough when the lightning strike arrives, and to reduce the residual voltage on the line after the surge protector to protect the safety of the equipment.
    The performance of the power supply lightning arrester determines its function. The flow rate, clamping voltage, and response time are the three main performance indicators of the power surge arrester. To clarify the meaning of these indicators requires some in-depth knowledge. The main working principle of the lightning arrester is to protect electrical equipment from lightning strikes by placing the instant lightning wave clamp at a safe voltage. This involves a problem of the size of the lightning. The international standard test index is generally 10kA, 8/20us (Figure 2) The lightning shock wave.


    What skills should lightning protectors have in the selection?
    1.Confirm power supply system
    First of all, you must determine what your power distribution system is like, whether it is TT, TN or IT system. After determining the power distribution system, you can choose the protection mode and wiring method of the lightning arrester to select the appropriate lightning arrester.
    For example, TN-C uses 3P lightning protection device, TN-S uses 4P, TT uses 3P+N, etc.
    2.Know the main parameters of the lightning arrester.
    FAQ


    Q: Can I get some samples?
    A: Yes, Sample orders welcomed.

    Q: Can I use my own Logo or design on goods?
    A: Yes, Customized logo and design on mass production are available.

    Q:What is the delivery time?
    A: 3 days for samples, 7-15 days for mass production.

    Q: What is the payment term?
    A: T/T, L/C at sight, West union , Paypal, etc.

    Quality Graphite Type 1 And Type 2 Surge Protection In 25KA For Data Centers for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong Uchi Electronics Co.,Ltd
    *Subject:
    *Message: